Skip to main navigation Skip to search Skip to main content

The relationship between coronary stent strut thickness and the incidences of clinical outcomes after drug-eluting stent implantation: A systematic review and meta-regression analysis

  • Akira Saito
  • , Zhehao Dai
  • , Masafumi Ono
  • , Takayoshi Kanie
  • , Yoshimitsu Takaoka
  • , Atsushi Mizuno
  • , Nobuyuki Komiyama
  • , Taku Asano*
  • *Corresponding author for this work
  • St. Luke's International University
  • The University of Tokyo
  • University of Galway
  • University of Pennsylvania

Research output: Contribution to journalArticleAcademicpeer-review

44 Downloads (Pure)

Abstract

Background: Drug-eluting stents (DESs) have been developed with thinner stent struts, and more biocompatible polymers and anti-proliferative drugs to improve the clinical performance. However, it remains unclear whether thinner struts are associated with favorable short- and long-term clinical outcomes such as target lesion revascularization (TLR), periprocedural myocardial infarction (PMI), and stent thrombosis (ST). Methods: We searched MEDLINE, Embase and other online sources for randomized controlled trials (RCTs) comparing clinical outcomes between a DES and other stent(s), with independent clinical event adjudication. We investigated stent-related events (TLR, PMI, and ST) in 5 years. Each outcome was analyzed with random-effects meta-regression model against strut thickness, then adjusted for DES generation and patient and lesion characteristics. Results: We identified 49 RCTs enrolling 97,465 patients, of which strut thickness ranged from 60 to 140 μm. Incidences of 1-year TLR, PMI, and early ST were reduced with thinner stent struts, when adjusted for stent generation (adjusted relative risk [RR] per 10 μm increase 1.12 [95% CI 1.04–1.21], 1.15 [95% CI 1.05–1.26], and 1.15 [95% CI 1.06–1.25], respectively). Strut thickness was not independently associated with incidences of 5-year TLR, late and very late ST. In addition, early DESs contributed to a higher incidence of very late ST (adjusted RR 2.97 [95% CI 1.36–6.50]). Conclusions: In this meta-regression analysis, a thinner strut thickness was associated with reduced incidences of early stent-related adverse events (1-year TLR, PMI, and early ST), but not with later events (5-year TLR, late ST, and very late ST).
Original languageEnglish
JournalCatheterization and cardiovascular interventions
Early online date2021
DOIs
Publication statusE-pub ahead of print - 2021

Keywords

  • drug-eluting stent
  • periprocedural myocardial infarction
  • stent generation
  • stent thrombosis
  • strut thickness
  • target lesion revascularization

Fingerprint

Dive into the research topics of 'The relationship between coronary stent strut thickness and the incidences of clinical outcomes after drug-eluting stent implantation: A systematic review and meta-regression analysis'. Together they form a unique fingerprint.

Cite this