Skip to main navigation Skip to search Skip to main content

Quality assurance of quantitative cardiac T1-mapping in multicenter clinical trials – A T1 phantom program from the hypertrophic cardiomyopathy registry (HCMR) study

  • Qiang Zhang*
  • , Konrad Werys
  • , Iulia A. Popescu
  • , Luca Biasiolli
  • , Ntobeko A. B. Ntusi
  • , Milind Desai
  • , Stefan L. Zimmerman
  • , Dipan J. Shah
  • , Kyle Autry
  • , Bette Kim
  • , Han W. Kim
  • , Elizabeth R. Jenista
  • , Steffen Huber
  • , James A. White
  • , Gerry P. McCann
  • , Saidi A. Mohiddin
  • , Redha Boubertakh
  • , Amedeo Chiribiri
  • , David Newby
  • , Sanjay Prasad
  • Aleksandra Radjenovic, Dana Dawson, Jeanette Schulz-Menger, Heiko Mahrholdt, Iacopo Carbone, Ornella Rimoldi, Stefano Colagrande, Linda Calistri, Michelle Michels, Mark B. M. Hofman, Lisa Anderson, Craig Broberg, Flett Andrew, Javier Sanz, Chiara Bucciarelli-Ducci, Kelvin Chow, David Higgins, David A. Broadbent, Scott Semple, Tarik Hafyane, Joanne Wormleighton, Michael Salerno, Taigang He, Sven Plein, Raymond Y. Kwong, Michael Jerosch-Herold, Christopher M. Kramer, Stefan Neubauer, Vanessa M. Ferreira, Stefan K. Piechnik
*Corresponding author for this work
  • University of Oxford
  • University of Cape Town
  • Cleveland Clinic Foundation
  • Johns Hopkins University
  • Houston Methodist
  • Icahn School of Medicine at Mount Sinai
  • Duke University Medical Center
  • Yale University School of Medicine
  • University of Calgary
  • University of Leicester
  • St Bartholomew's Hospital
  • Guy’s Hospital
  • University of Edinburgh
  • Imperial College London
  • Veterinary and Life Sciences
  • University of Aberdeen
  • Charité – Universitätsmedizin Berlin
  • Robert Bosch Foundation
  • University of Rome La Sapienza
  • Vita-Salute San Raffaele University
  • University of Florence
  • Erasmus University Rotterdam
  • St. George's University of London
  • Oregon Health and Science University
  • University Hospital Southampton NHS Foundation Trust
  • University of Bristol
  • Siemens
  • Philips Electronics UK Limited, Surrey, UK
  • University of Leeds
  • University of Montreal
  • University Hospitals of Leicester NHS Trust
  • University of Virginia
  • Harvard Medical School
  • Brigham and Women’s Hospital

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Background: Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials. Purpose: To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use. Methods: MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites. Results: T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R2 > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions. Conclusions: The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials.
Original languageEnglish
Pages (from-to)251-258
Number of pages8
JournalInternational journal of cardiology
Volume330
Early online date2021
DOIs
Publication statusPublished - 1 May 2021

Keywords

  • Cardiac MRI
  • Multicenter study
  • Phantom study
  • Quality assurance
  • Quantitative T1-mapping
  • Standardization

Fingerprint

Dive into the research topics of 'Quality assurance of quantitative cardiac T1-mapping in multicenter clinical trials – A T1 phantom program from the hypertrophic cardiomyopathy registry (HCMR) study'. Together they form a unique fingerprint.

Cite this