PARAMETRIC IMAGING OF DUAL-TIME-WINDOW [18F]FLUTEMETAMOL AND [18F]FLORBETABEN STUDIES

  • Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands; Department of Neurology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands; Neurosurgical Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands; Department of Biomedical Engineering & Physics AUMC...
  • Hospital del Mar Medical Research Institute (IMIM), Barcelona, Spain

Research output: Contribution to journalArticleAcademicpeer-review

4 Downloads (Pure)

Abstract

Optimal pharmacokinetic models for quantifying amyloid beta (Aβ) burden using both [18F]flutemetamol and [18F]florbetaben scans have previously been identified at a region of interest (ROI) level. The purpose of this study was to determine optimal quantitative methods for parametric analyses of [18F]flutemetamol and [18F]florbetaben scans. Forty-six participants were scanned on a PET/MR scanner using a dual-time-window protocol and either [18F]flutemetamol (N=24) or [18F]florbetaben (N=22). The following parametric approaches were used to derive DVR estimates: reference Logan (RLogan), receptor parametric mapping (RPM), two-step simplified reference tissue model (SRTM2) and multilinear reference tissue models (MRTM0, MRTM1, MRTM2), all with cerebellar grey matter as reference tissue. In addition, a standardized uptake value ratio (SUVR) was calculated for the 90-110 min post injection interval. All parametric images were assessed visually. Regional outcome measures were compared with those from a validated ROI method, i.e. DVR derived using RLogan. Visually, RPM, and SRTM2 performed best across tracers and, in addition to SUVR, provided highest AUC values for differentiating between Aβ-positive vs Aβ-negative scans ([18F]flutemetamol: range AUC=0.96-0.97 [18F]florbetaben: range AUC=0.83-0.85). Outcome parameters of most methods were highly correlated with the reference method (R2≥0.87), while lowest correlation were observed for MRTM2 (R2=0.71-0.80). Furthermore, bias was low (≤ 5%) and independent of underlying amyloid burden for MRTM0 and MRTM1. The optimal parametric method differed per evaluated aspect; however, the best compromise across aspects was found for MRTM0 followed by SRTM2, for both tracers. SRTM2 is the preferred method for parametric imaging because, in addition to its good performance, it has the advantage of providing a measure of relative perfusion (R1), which is useful for measuring disease progression.

Original languageEnglish
Article number117953
Pages (from-to)117953
JournalNeuroImage
Volume234
Early online date5 Mar 2021
DOIs
Publication statusPublished - 1 Jul 2021

Keywords

  • Amyloid PET
  • PET quantification
  • Parametric imaging
  • [ F]florbetaben
  • [ F]flutemetamol