Influence of tumour depth, blood absorption and autofluorescence on measurements of exogenous fluorophores in tissue

  • A. E. Saarnak
  • , T. Rodrigues
  • , J. Schwartz
  • , A. L. Moore
  • , T. A. Moore
  • , D. Gust
  • , M. J. C. van Gemert
  • , H. J. C. M. Sterenborg
  • , S. Thomsen

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

We investigated the influence of tumour depth and differences in blood concentration and autofluorescence between tumour and normal tissue on the fluorescence of a tumour-localising agent. Carotenoporphyrin, CP(Me)(3), mas injected into rats and nude mice with intradermal tumours. On the tumours an incision was made, uncovering 2 mm(2) of the tumour, and fluorescence measurements, including excitation-emission maps and fluorescence ratios, were made on skin. covered and uncovered tumour, The measured fluorescence ratio in the uncovered tumour showed a three- to tenfold increase compared to the covered tumour, We used a one-dimensional layered tissue model to analyse the data, In conclusion, even with a high tumour-selectivity deeper lying tumours cannot always be detected, particularly if the tumour has a high blood concentration or low autofluorescence intensity
Original languageEnglish
Pages (from-to)22-31
JournalLasers in medical science
Volume13
Issue number1
DOIs
Publication statusPublished - 1998