Skip to main navigation Skip to search Skip to main content

Influence of daily setup measurements and corrections on the estimated delivered dose during IMRT treatment of prostate cancer patients

  • Paul M. A. van Haaren
  • , Arjan Bel
  • , Pieter Hofman
  • , Marco van Vulpen
  • , Alexis N. T. J. Kotte
  • , Uulke A. van der Heide

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Purpose: To evaluate the impact of marker-based position verification, using daily imaging and an off-line correction protocol, by calculating the delivered dose to prostate, rectum and bladder. Methods: Prostate cancer patients (n = 217) were treated with IMRT, receiving 35 daily fractions. Plans with five beams were optimized taking target coverage (CTV, boost) and organs-at-risk (rectum and bladder) into account. PTV margins were 8 mm. Prostate position was verified daily using implanted fiducial gold markers by imaging the first segment of all the five beams on an EPID. Setup deviations were corrected off-line using an adapted shrinking-action-level protocol. The estimated delivered dose, including daily organ movements, Was calculated using a version of PLATO's dose engine, enabling batch processing of large numbers of patients. The dose was calculated inclusion of setup corrections, and was evaluated relative to the original static plan. The marker-based measurements were considered representative for all organs. Results: Daily organ movements would result in an underdosage of 2-3 Gy to CTV and boost volume relative to the original plan, which was prevented by daily setup corrections. The dose to rectum and bladder was oil average unchanged, but a large spread was introduced by organ movements, which was reduced by including setup corrections. Conclusions: Without position verification and setup corrections, margins of 8mm would be insufficient to account for position uncertainties during IMRT of prostate cancer. With the daily off-line correction protocol, the remaining variations are accommodated adequately. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 90 (2009) 291-298
Original languageEnglish
Pages (from-to)291-298
JournalRadiotherapy and oncology
Volume90
Issue number3
DOIs
Publication statusPublished - 2009

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Influence of daily setup measurements and corrections on the estimated delivered dose during IMRT treatment of prostate cancer patients'. Together they form a unique fingerprint.

Cite this