Skip to main navigation Skip to search Skip to main content

Image-guided radiotherapy for breast cancer patients: surgical clips as surrogate for breast excision cavity

  • Rajko Topolnjak
  • , Peter de Ruiter
  • , Peter Remeijer
  • , Corine van Vliet-Vroegindeweij
  • , Coen Rasch
  • , Jan-Jakob Sonke

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

To determine the use of surgical clips as a surrogate for localization of the excision cavity and to quantify the stability of the clips' positions during the course of external beam radiotherapy for breast cancer patients, using cone beam computed tomography (CBCT) scans. Twenty-one breast cancer patients with surgical clips placed in the breast excision cavity were treated in a supine position with 28 daily fractions. CBCT scans were regularly acquired for a setup correction protocol. Retrospectively, the CBCT scans were registered to the planning CT scans, using gray-value registration of the excision cavity region and chamfer matching of the clips. Subsequently, residual setup errors (systematic [Σ] and random [σ]) of the excision cavity were estimated relative to the clips' registration. Finally, the stability of the clips' positions were quantified as the movement of each separate clip according to the center of gravity of the excision cavity. When clips were used for online setup corrections, the residual errors of the excision cavity were Σ(left-right) = 1.2, σ(left-right) = 1.0; Σ(cranial-caudal) = 1.3, σ(cranial-caudal) = 1.2; and Σ(anterior-posterior) = 0.7, σ(anterior-posterior) = 0.9 mm. Furthermore, the average distance (over all patients) between the clips and centers of gravity of the excision cavities was 18.8 mm (on the planning CT) and was reduced to 17.4 mm (measured on the last CBCT scan). Clips move in the direction of the center of gravity of the excision cavity, on average, 1.4 mm. The clips are good surrogates for locating the excision cavity and providing small residual errors
Original languageEnglish
Pages (from-to)e187-e195
JournalInternational journal of radiation oncology, biology, physics
Volume81
Issue number3
DOIs
Publication statusPublished - 2011

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Image-guided radiotherapy for breast cancer patients: surgical clips as surrogate for breast excision cavity'. Together they form a unique fingerprint.

Cite this