Skip to main navigation Skip to search Skip to main content

Head-to-head evaluation of host blood biomarkers for point-of-care TB triage: diagnostic accuracy study

  • Makerere University
  • University of Amsterdam
  • National Tuberculosis Reference Laboratory/WHO Supranational Reference Laboratory
  • Stellenbosch University

Research output: Contribution to journal › Article › Academic › peer-review

5 Downloads (Pure)

Abstract

Global tuberculosis (TB) incidence is slowly decreasing, partly because undiagnosed TB continues to fuel transmission. Point-of-care TB triage tests (TTTs) performed near a patient or at the site of patient care may help bridge this gap, but head-to-head comparisons of different host blood biomarkers within the same cohort are limited. In ambulatory adults in Uganda aged ≥15 years with any cough, fever, weight loss, or night sweats, we evaluated the diagnostic accuracy of C-reactive protein (CRP), monocyte-to-lymphocyte ratio (MLR), interferon-gamma-induced protein 10 (IP-10), and hemoglobin (anemia) head-to-head using a reference standard comprised of culture and∕or Xpert MTB∕RIF Ultra. Cut-offs of CRP and anemia were from World Health Organization (WHO) recommendations, MLR from the literature, and IP-10 from Youden’s index. We included 623 participants (193 people living with HIV [PLWHIV]), of whom 111 (18%) were reference standard-positive. Sensitivity and specificity (95% CI) were 91% (84%–96%) and 78% (74%–81%) for CRP (≥10 mg∕L); 72% (63%–78%) and 80% (77%–84%) for MLR (≥0.378); 86% (79%–92%) and 73% (69%–77%) for IP-10 (≥28.75); 69% (60%–78%) and 76% (72%–80%) for anemia (<12 g∕dL [female], <13 g∕dL [male]), respectively. At 90% sensitivity, specificity was 76% (58%–83%) for CRP; 62% (47%–74%) for MLR; 64% (47%–75%) for IP-10, and 28% (17%–51%) for anemia. There was no significant difference for any of the four TTTs in diagnostic odds ratio between participants with and without a history of previous TB, between smokers and non-smokers, and between males and females. However, MLR performed significantly (P = 0.001) worse in PLWHIV. Combining two index tests in parallel testing improved sensitivity up to 96% at the expense of reduced specificity. The applicable WHO minimum target product profile of 90% sensitivity and 60% specificity was met for CRP irrespective of HIV status, and for IP-10 and MLR when cut-offs were adjusted. Sex, prior history of smoking, and TB did not impact diagnostic performance. Parallel testing may be suitable in high TB prevalence settings, where minimizing missed cases and ensuring timely referral for confirmatory testing are priorities.

Original languageEnglish
Article numbere00046-26
JournalJournal of clinical microbiology
Volume64
Issue number8
DOIs
Publication statusPublished - 1 Aug 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 5 - Gender Equality
    SDG 5 Gender Equality

Fingerprint

Dive into the research topics of 'Head-to-head evaluation of host blood biomarkers for point-of-care TB triage: diagnostic accuracy study'. Together they form a unique fingerprint.

Cite this