Skip to main navigation Skip to search Skip to main content

Electronic nose breathprints are independent of acute changes in airway caliber in asthma

  • Zsofia Lazar
  • , Niki Fens
  • , Jan Van der Maten
  • , Marc P. van der Schee
  • , Ariane H. Wagener
  • , Selma B. de Nijs
  • , Erica Dijkers
  • , Peter J. Sterk

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Molecular profiling of exhaled volatile organic compounds (VOC) by electronic nose technology provides breathprints that discriminate between patients with different inflammatory airway diseases, such as asthma and COPD. However, it is unknown whether this is determined by differences in airway caliber. We hypothesized that breathprints obtained by electronic nose are independent of acute changes in airway caliber in asthma. Ten patients with stable asthma underwent methacholine provocation (Visit 1) and sham challenge with isotonic saline (Visit 2). At Visit 1, exhaled air was repetitively collected pre-challenge, after reaching the provocative concentration (PC(20)) causing 20% fall in forced expiratory volume in 1 second (FEV(1)) and after subsequent salbutamol inhalation. At Visit 2, breath was collected pre-challenge, post-saline and post-salbutamol. At each occasion, an expiratory vital capacity was collected after 5 min of tidal breathing through an inspiratory VOC-filter in a Tedlar bag and sampled by electronic nose (Cyranose 320). Breathprints were analyzed with principal component analysis and individual factors were compared with mixed model analysis followed by pairwise comparisons. Inhalation of methacholine led to a 30.8 ± 3.3% fall in FEV(1) and was followed by a significant change in breathprint (p = 0.04). Saline inhalation did not induce a significant change in FEV(1), but altered the breathprint (p = 0.01). However, the breathprint obtained after the methacholine provocation was not significantly different from that after saline challenge (p = 0.27). The molecular profile of exhaled air in patients with asthma is altered by nebulized aerosols, but is not affected by acute changes in airway caliber. Our data demonstrate that breathprints by electronic nose are not confounded by the level of airway obstruction
Original languageEnglish
Pages (from-to)9127-9138
JournalSensors (Basel, Switzerland)
Volume10
Issue number10
DOIs
Publication statusPublished - 2010

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Electronic nose breathprints are independent of acute changes in airway caliber in asthma'. Together they form a unique fingerprint.

Cite this