Abstract
CT colonography (CTC) is one of the recommended methods for colorectal cancer screening. The subject's preparation is one of the most burdensome aspects of CTC with a cathartic bowel preparation. Tagging of the bowel content with an oral contrast medium facilitates CTC with limited bowel preparation. Unfortunately, such preparations adversely affect the 3-D image quality. Thus far, data acquired after very limited bowel preparation were evaluated with a 2-D reading strategy only. Existing cleansing algorithms do not work sufficiently well to allow a primary 3-D reading strategy. We developed an electronic cleansing algorithm, aimed to realize optimal 3-D image quality for low-dose CTC with 24-h limited bowel preparation. The method employs a principal curvature flow algorithm to remove heterogeneities within poorly tagged fecal residue. In addition, a pattern recognition-based approach is used to prevent polyp-like protrusions on the colon surface from being removed by the method. Two experts independently evaluated 40 CTC cases by means of a primary 2-D approach without involvement of electronic cleansing as well as by a primary 3-D method after electronic cleansing. The data contained four variations of 24-h limited bowel preparation and was based on a low radiation dose scanning protocol. The sensitivity for lesions ≥ 6 mm was significantly higher for the primary 3-D reading strategy (84%) than for the primary 2-D reading strategy (68%) (p = 0.031). The reading time was increased from 5:39 min (2-D) to 7:09 min (3-D) (p = 0.005); the readers' confidence was reduced from 2.3 (2-D) to 2.1 (3-D) ( p = 0.013) on a three-point Likert scale. Polyp conspicuity for cleansed submerged lesions was similar to not submerged lesions (p = 0.06). To our knowledge, this study is the first to describe and clinically validate an electronic cleansing algorithm that facilitates low-dose CTC with 24-h limited bowel preparation
| Original language | English |
|---|---|
| Pages (from-to) | 3036-3045 |
| Journal | IEEE transactions on bio-medical engineering |
| Volume | 60 |
| Issue number | 11 |
| DOIs | |
| Publication status | Published - 2013 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Fingerprint
Dive into the research topics of 'Electronic cleansing for 24-h limited bowel preparation CT colonography using principal curvature flow'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver