Efficacy of an implantable cardioverter-defibrillator in a neonate with LQT3 associated arrhythmias

  • Arend D. J. ten Harkel
  • , Maarten Witsenburg
  • , Peter L. de Jong
  • , Luc Jordaens
  • , Marjolein Wijman
  • , Arthur A. M. Wilde

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

We present a case in which LQTS induced severe prenatal and neonatal arrhythmias. LQT3 was diagnosed (mutation R1623Q). Short-acting beta-blockers were ineffective as well as sotalol and mexiletine in preventing recurrent ventricular arrhythmias. An ICD was implanted at the age of 7 months (weight and length of the infant at implantation 6 kg and 60 cm respectively). Flecainide was prescribed in addition to the ICD implantation. After an appropriate shock the flecainide plasma levels were shown to be subtherapeutic. Readjustment of the flecainide dose resulted in adequate plasma levels. No further shocks occurred during a further 17 months follow-up period. The combination of an active can with a subcutaneous patch proved feasible, and lifesaving shocks occurred at 7 months after implantation. (C) 2004 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved
Original languageEnglish
Pages (from-to)77-84
JournalEuropace : European pacing, arrhythmias, and cardiac electrophysiology
Volume7
Issue number1
DOIs
Publication statusPublished - 2005

Fingerprint

Dive into the research topics of 'Efficacy of an implantable cardioverter-defibrillator in a neonate with LQT3 associated arrhythmias'. Together they form a unique fingerprint.