Abstract
A high-performance liquid chromatographic method is presented for the determination of urinary acylcarnitines. After solid phase extraction on silica columns the acylcarnitines are converted to 4'-bromophenacyl esters with 4'-bromophenacylbromide in the presence of N,N-diisopropylethylamine. Complete derivatization was achieved at 37 degrees C within 30 min. The 4'-bromophenacyl esters were separated by high-performance liquid chromatography on a Hypersil BDS C8 reversed-phase column with a binary gradient containing varying proportions of acetonitrile, water and 0.1 M triethylamine phosphate buffer. Essentially baseline separation was obtained with a standard mixture containing 4'-bromophenacyl esters of carnitine and synthetic acylcarnitines of increasing chain length ranging from acetyl- to palmitoylcarnitine. The method was used to obtain urinary acylcarnitine profiles from patients with propionic, methylmalonic and isovaleric acidemia and with medium-chain and multiple acyl-CoA dehydrogenase deficiency. Quantification of the acylcarnitines was achieved using undecanoylcarnitine as internal standard
| Original language | English |
|---|---|
| Pages (from-to) | 53-61 |
| Journal | Clinica chimica acta; international journal of clinical chemistry |
| Volume | 216 |
| Issue number | 1-2 |
| DOIs | |
| Publication status | Published - 1993 |
Fingerprint
Dive into the research topics of 'Determination of acylcarnitines in urine of patients with inborn errors of metabolism using high-performance liquid chromatography after derivatization with 4'-bromophenacylbromide'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver