Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke

  • MR CLEAN Trial Investigators
  • Department of Biomedical Engineering and Physics
  • Radboud University Medical Center, Radboud Institute for Health Sciences
  • Maastricht University Medical Center +, part of the Nijmegen/Eindhoven/Maastricht Haemophilia Treatment Center (HTC).
  • Erasmus Universiteit: Department of Gastroenterology and Hepatology, Erasmus Medical Center, University Medical Center Rotterdam, Rotterdam, The Netherlands and the Department of Gastroenterology and Hepatology, Academic Medical Center, University Medical Center, Amsterdam,
  • Department of Radiology and Nuclear Medicine, Amsterdam, Netherlands
  • Department of Radiology and Nuclear Medicine, Rotterdam, Netherlands
  • Department of Neurology, Rotterdam, Netherlands
  • Department of Biomedical Engineering and Physics, Amsterdam, Netherlands
  • Department of Radiology, Leiden, Netherlands
  • Department of Radiology, Nijmegen, Netherlands
  • Department of Radiology, Maastricht, Netherlands
  • Department of Neurology, Maastricht, Netherlands
  • Department of Neurology, Amsterdam, Netherlands

Research output: Contribution to journalArticleAcademicpeer-review

59 Downloads (Pure)

Abstract

Background and purpose: CT perfusion (CTP) might support decision making in patients with acute ischemic stroke by providing perfusion maps of ischemic tissue. Currently, the reliability of CTP is hampered by varying results between different post-processing software packages. The purpose of this study is to compare ischemic core volumes estimated by IntelliSpace Portal (ISP) and syngo.via with core volumes as estimated by RAPID. Methods: Thirty-five CTP datasets from patients in the MR CLEAN trial were post-processed. Core volumes were estimated with ISP using default settings and with syngo.via using three different settings: default settings (method A); additional smoothing filter (method B); and adjusted settings (method C). The results were compared with RAPID. Agreement between methods was assessed using Bland-Altman analysis and intraclass correlation coefficient (ICC). Accuracy for detecting volumes up to 25 mL, 50 mL, and 70 mL was assessed. Final infarct volumes were determined on follow-up non-contrast CT. Results: Median core volume was 50 mL with ISP, 41 mL with syngo.via method A, 20 mL with method B, 36 mL with method C, and 11 mL with RAPID. Agreement ranged from poor (ISP: ICC 0.41; method A: ICC 0.23) to good (method B: ICC 0.83; method C: ICC 0.85). The bias (1.8 mL) and limits of agreement (-27, 31 mL) were the smallest with syngo.via with additional smoothing (method B). Agreement for detecting core volumes ≤25 mL with ISP was 54% and 57%, 85% and 74% for syngo.via methods A, B, and C, respectively. Conclusion: Best agreement with RAPID software is provided by syngo.via default settings with additional smoothing. Moreover, this method has the highest agreement in categorizing patients with small core volumes.
Original languageEnglish
Pages (from-to)1249-1256
Number of pages8
JournalJournal of neurointerventional surgery
Volume11
Issue number12
DOIs
Publication statusPublished - 1 Dec 2019

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Aged
  • Aged, 80 and over
  • Brain Ischemia/diagnostic imaging
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Perfusion Imaging/methods
  • Prospective Studies
  • Reproducibility of Results
  • Software
  • Stroke/diagnostic imaging
  • Tomography, X-Ray Computed/methods

Fingerprint

Dive into the research topics of 'Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke'. Together they form a unique fingerprint.

Cite this