Skip to main navigation Skip to search Skip to main content

Comparison between elecsys HBsAg II and architect HBsAg QT assays for quantification of hepatitis B surface antigen among patients coinfected with HIV and hepatitis B virus

  • Sarah Maylin
  • , Anders Boyd
  • , Constance Delaugerre
  • , Fabien Zoulim
  • , Fabien Lavocat
  • , François Simon
  • , Pierre-Marie Girard
  • , Karine Lacombe
  • Université Paris 7
  • Inserm
  • Université Paris Diderot
  • Centre de Recherche en Cancérologie de Lyon
  • Hôpital de la Croix-Rousse
  • Universite Claude Bernard Lyon 1
  • Sorbonne Université

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Hepatitis B surface antigen (HBsAg) quantification has been steadily gaining interest as a clinical marker of therapeutic efficacy, for which two commercial assays are currently available: Architect HBsAg QT (Architect) and Elecsys HBsAg II (Elecsys). HBsAg quantification was evaluated using both assays in 126 human immunodeficiency virus (HIV) and hepatitis B virus (HBV)- coinfected patients initiating treatment with tenofovir dipivoxil fumarate. Linear regression and correlation were used to establish the relationship between the two methods. Bland-Altman analysis was performed to determine mean between-assay difference and limits of agreement (LOA) (±2 standard deviations [SD]) both overall and stratified on HBV (hepatitis B envelope antigen [HBeAg] status, replication, genotype, HBV mutants) or HIV (CD4 + cell count) cofactors. There was a significant correlation between Elecsys and Architect assays (correlation coefficient, r = 0.959; P<0.001). HBsAg quantification using the Elecsys assay was on average 0.200 log 10 IU/ml (LOA,-0.500, 0.800) higher than that using Architect, which was consistent across levels of CD4 + cell count, presence of precore and YMDD mutations, and HBeAg status. A slightly larger mean between-assay difference was observed with genotypes A and G (0.196 and 0.201, respectively) versus HBV genotypes D and E (0.036 and 0.030, respectively). Mutations on the S region at position s120/s145 were the only determinant in which the mean between-assay difference in HBsAg quantification was lower than the null value (-0.078). In conclusion, the Elecsys assay, with automatic on-board dilution, is capable of quantifying serum HBsAg levels in HIV-HBV-coinfected patients, with very high correlation with the Architect assay. Copyright © 2012, American Society for Microbiology. All Rights Reserved.
Original languageEnglish
Pages (from-to)242-248
Number of pages7
JournalClinical and vaccine immunology
Volume19
Issue number2
DOIs
Publication statusPublished - Feb 2012
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Adenine/analogs & derivatives
  • Adult
  • Anti-HIV Agents/therapeutic use
  • CD4 Lymphocyte Count
  • Coinfection/immunology
  • Female
  • Genotype
  • HIV Infections/complications
  • Hepatitis B/complications
  • Hepatitis B Surface Antigens/blood
  • Hepatitis B e Antigens/immunology
  • Hepatitis B virus/immunology
  • Humans
  • Male
  • Middle Aged
  • Organophosphonates/therapeutic use
  • Reagent Kits, Diagnostic
  • Tenofovir

Fingerprint

Dive into the research topics of 'Comparison between elecsys HBsAg II and architect HBsAg QT assays for quantification of hepatitis B surface antigen among patients coinfected with HIV and hepatitis B virus'. Together they form a unique fingerprint.

Cite this