TY - JOUR
T1 - Central venous pressure and dynamic indices to assess fluid appropriateness in critically ill patients
T2 - A pilot study
AU - Prezioso, Chiara
AU - Trotta, Roberta
AU - Cavallo, Erika
AU - Fusina, Federica
AU - Malpetti, Elena
AU - Albani, Filippo
AU - Caserta, Rosalba
AU - Rosano, Antonio
AU - Natalini, Giuseppe
N1 - Publisher Copyright:
© 2023 Prezioso et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2023/5/1
Y1 - 2023/5/1
N2 - Background The correct identification of the appropriateness of fluid administration is important for the treatment of critically ill patients. Static and dynamic indices used to identify fluid responsiveness have been developed throughout the years, nonetheless fluid responsiveness does not indicate that fluid administration is appropriate, and indexes to evaluate appropriateness of fluid administration are lacking. The aim of this study was to evaluate if central venous pressure (CVP) anddynamic indices could correctly identify fluid appropriateness for critically ill patients. Methods Data from 31 ICU patients, for a total of 53 observations, was included in the analysis. Patients were divided into two cohorts based on the appropriateness of fluid administration. Fluid appropriateness was defined in presence of a low cardiac index (< 2.5 l/min/m
2) without any sign of fluid overload, as assessed by global end-diastolic volume index, extravascular lung water index or pulmonary artery occlusion pressure. Results For 10 patients, fluid administration was deemed appropriate, while for 21 patients it was deemed inappropriate. Central venous pressure was not different between the two cohorts (mean CVP 11 (4) mmHg in the fluid inappropriate group, 12 (4) mmHg in the fluid appropriate group, p 0.58). The same is true for pulse pressure variation (median PPV 5 [2, 9] % in the fluid inappropriate group, 4 [3, 13] % in the fluid appropriate group, p 0.57), for inferior vena cava distensibility (mean inferior vena cava distensibility 24 (14) % in the fluid inappropriate group, 22 (16) % in the fluid appropriate group, p 0.75) and for changes in end tidal carbon dioxide during a passive leg raising test (median d.E
TCO
2 1.5 [0.0, 2.0]% in the fluid inappropriate group, 1.0 [0.0, 2.0] % in the fluid appropriate group, p 0.98). There was no association between static and dynamic indices and fluid appropriateness. Conclusions Central venous pressure, pulse pressure variation, changes in end tidal carbon dioxide during a passive leg raising test, inferior vena cava distensibility were not associated with fluid appropriateness in our cohorts.
AB - Background The correct identification of the appropriateness of fluid administration is important for the treatment of critically ill patients. Static and dynamic indices used to identify fluid responsiveness have been developed throughout the years, nonetheless fluid responsiveness does not indicate that fluid administration is appropriate, and indexes to evaluate appropriateness of fluid administration are lacking. The aim of this study was to evaluate if central venous pressure (CVP) anddynamic indices could correctly identify fluid appropriateness for critically ill patients. Methods Data from 31 ICU patients, for a total of 53 observations, was included in the analysis. Patients were divided into two cohorts based on the appropriateness of fluid administration. Fluid appropriateness was defined in presence of a low cardiac index (< 2.5 l/min/m
2) without any sign of fluid overload, as assessed by global end-diastolic volume index, extravascular lung water index or pulmonary artery occlusion pressure. Results For 10 patients, fluid administration was deemed appropriate, while for 21 patients it was deemed inappropriate. Central venous pressure was not different between the two cohorts (mean CVP 11 (4) mmHg in the fluid inappropriate group, 12 (4) mmHg in the fluid appropriate group, p 0.58). The same is true for pulse pressure variation (median PPV 5 [2, 9] % in the fluid inappropriate group, 4 [3, 13] % in the fluid appropriate group, p 0.57), for inferior vena cava distensibility (mean inferior vena cava distensibility 24 (14) % in the fluid inappropriate group, 22 (16) % in the fluid appropriate group, p 0.75) and for changes in end tidal carbon dioxide during a passive leg raising test (median d.E
TCO
2 1.5 [0.0, 2.0]% in the fluid inappropriate group, 1.0 [0.0, 2.0] % in the fluid appropriate group, p 0.98). There was no association between static and dynamic indices and fluid appropriateness. Conclusions Central venous pressure, pulse pressure variation, changes in end tidal carbon dioxide during a passive leg raising test, inferior vena cava distensibility were not associated with fluid appropriateness in our cohorts.
UR - https://www.scopus.com/pages/publications/85159759231
U2 - 10.1371/journal.pone.0285935
DO - 10.1371/journal.pone.0285935
M3 - Article
C2 - 37200296
SN - 1932-6203
VL - 18
JO - PLoS ONE
JF - PLoS ONE
IS - 5 May
M1 - e0285935
ER -