Abstract

Background: The distribution of radiation exposure on the body surface of interventional echocardiographers during structural heart disease (SHD) procedures is unclear. Objectives: This study estimated and visualized radiation exposure on the body surface of interventional echocardiographers performing transesophageal echocardiography by computer simulations and real-life measurements of radiation exposure during SHD procedures. Methods: A Monte Carlo simulation was performed to clarify the absorbed dose distribution of radiation on the body surface of interventional echocardiographers. The real-life radiation exposure was measured during 79 consecutive procedures (44 transcatheter edge-to-edge repairs of the mitral valve and 35 transcatheter aortic valve replacements [TAVRs]). Results: The simulation demonstrated high-dose exposure areas (>20 μGy/h) in the right half of the body, especially the waist and lower body, in all fluoroscopic directions caused by scattered radiation from the bottom edge of the patient bed. High-dose exposure occurred when obtaining posterior-anterior and cusp-overlap views. The real-life exposure measurements were consistent with the simulation estimates: interventional echocardiographers were more exposed to radiation at their waist in transcatheter edge-to-edge repair than in TAVR procedures (median 0.334 μSv/mGy vs 0.053 μSv/mGy; P < 0.001) and in TAVR with self-expanding valves than in those with balloon-expandable valves (median 0.067 μSv/mGy vs 0.039 μSv/mGy; P < 0.01) when the posterior-anterior or the right anterior oblique angle fluoroscopic directions were used. Conclusions: During SHD procedures, the right waist and lower body of interventional echocardiographers were exposed to high radiation doses. Exposure dose varied between different C-arm projections. Interventional echocardiographers, especially young women, should be educated regarding radiation exposure during these procedures.

Original languageEnglish
Pages (from-to)301-309
Number of pages9
JournalJACC: Asia
Volume3
Issue number2
DOIs
Publication statusPublished - 1 Apr 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • echocardiologist
  • female doctor
  • interventional echocardiographer
  • radiation exposure
  • structural heart disease
  • transesophageal echocardiography

Fingerprint

Dive into the research topics of 'Body Surface Radiation Exposure in Interventional Echocardiographers During Structural Heart Disease Procedures'. Together they form a unique fingerprint.

Cite this