Abstract

The GluCath® intra-arterial continuous glucose monitoring (IA-CGM) system uses a novel quenched chemical fluorescence sensing mechanism to optically measure blood glucose when deployed in the radial artery. The aim of this study was to compare the accuracy of the IA-CGM and the FreeStyle Navigator® subcutaneous continuous glucose monitoring (SC-CGM) system with standard care. After admission to the intensive care unit (ICU), the IA-CGM was inserted via a 20 gauge radial arterial study catheter and the SC-CGM was placed at the abdominal wall of postoperative cardiac surgery patients with an expected ICU length of stay > 24 hours. Each device was calibrated according to manufacturer instructions. Glucose values of both CGM systems were blinded for the clinical staff. Reference blood glucose samples were collected from the study catheter every 1-2 hours for at least 24 hours and analyzed on a Radiometer ABL blood gas analyzer. The IA-CGM and SC-CGM sensors were successfully inserted in 8 subjects. Accuracy assessment was performed with 183 paired points: 85.8% of the IA-CGM measurements and 84.2% of the SC-CGM measurements met ISO 15197:2003 glucometer criteria (within 20%) across a 79-248 mg/dl (4.4-13.8 mmol/L) glucose range. Overall ± SD mean absolute relative difference was 12.3 ± 11.3% for IA-CGM and 11.1 ± 8.3% for SC-CGM (difference -1.2%, 95% CI -3.3 to 0.8; P = .24). The IA-CGM system directly measured arterial blood glucose and did not interfere with clinical care. However, accuracy was similar to that of the less invasive SC-CGM device
Original languageEnglish
Pages (from-to)663-667
JournalJournal of diabetes science and technology (Online)
Volume9
Issue number3
DOIs
Publication statusPublished - 2015

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  3. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure
  4. SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production

Fingerprint

Dive into the research topics of 'Accuracy of Intra-arterial and Subcutaneous Continuous Glucose Monitoring in Postoperative Cardiac Surgery Patients in the ICU'. Together they form a unique fingerprint.

Cite this