Skip to main navigation Skip to search Skip to main content

A New In Vitro Co-Culture Model Using Magnetic Force-Based Nanotechnology

  • Hiroki Takanari*
  • , Keiko Miwa
  • , XianMing Fu
  • , Junichi Nakai
  • , Akira Ito
  • , Kousuke Ino
  • , Hiroyuki Honda
  • , Wataru Tonomura
  • , Satoshi Konishi
  • , Tobias Opthof
  • , Marcel A. G. van der Heyden
  • , Itsuo Kodama
  • , Jong-Kook Lee
  • *Corresponding author for this work
  • Oita University
  • Nagoya University
  • University Medical Center Utrecht
  • The University of Osaka
  • Central South University
  • Saitama University
  • Kyushu University
  • Ritsumeikan University
  • Amsterdam UMC - University of Amsterdam

Research output: Contribution to journalArticleAcademicpeer-review

7 Downloads (Pure)

Abstract

Skeletal myoblast (SkMB) transplantation has been conducted as a therapeutic strategy for severe heart failure. However, arrhythmogenicity following transplantation remains unsolved. We developed an in vitro model of myoblast transplantation with “patterned” or “randomly-mixed” co-culture of SkMBs and cardiomyocytes enabling subsequent electrophysiological, and arrhythmogenic evaluation. SkMBs were magnetically labeled with magnetite nanoparticles and co-cultured with neonatal rat ventricular myocytes (NRVMs) on multi-electrode arrays. SkMBs were patterned by a magnet beneath the arrays. Excitation synchronicity was evaluated by Ca2+ imaging using a gene-encoded Ca2+ indicator, G-CaMP2. In the monoculture of NRVMs (control), conduction was well-organized. In the randomly-mixed co-culture of NRVMs and SkMBs (random group), there was inhomogeneous conduction from multiple origins. In the “patterned” co-culture where an en bloc SKMB-layer was inserted into the NRVM-layer, excitation homogenously propagated although conduction was distorted by the SkMB-area. The 4-mm distance conduction time (CT) in the random group was significantly longer (197 ± 126 ms) than in control (17 ± 3 ms). In the patterned group, CT through NRVM-area did not change (25 ± 3 ms), although CT through the SkMB-area was significantly longer (132 ± 77 ms). The intervals between spontaneous excitation varied beat-to-beat in the random group, while regular beating was recorded in the control and patterned groups. Synchronized Ca2+ transients of NRVMs were observed in the patterned group, whereas those in the random group were asynchronous. Patterned alignment of SkMBs is feasible with magnetic nanoparticles. Using the novel in vitro model mimicking cell transplantation, it may become possible to predict arrhythmogenicity due to heterogenous cell transplantation. J. Cell. Physiol. 231: 2249–2256, 2016. © 2016 Wiley Periodicals, Inc.
Original languageEnglish
Pages (from-to)2249-2256
JournalJournal of cellular physiology
Volume231
Issue number10
DOIs
Publication statusPublished - 1 Oct 2016
Externally publishedYes

Fingerprint

Dive into the research topics of 'A New In Vitro Co-Culture Model Using Magnetic Force-Based Nanotechnology'. Together they form a unique fingerprint.

Cite this